كابلات NSComm MPO 16F APC إلى 8×LC UPC Duplex Harness، 16 ألياف، أحادي الوضع (OS2، G.657.A1)، OFNR، كروس أوفر

Proven Expertise, Trusted Solutions
- 8 Years, 100+ Countries
- 10000+ Customers/Projects
- CCIE, HCIE, H3CIE, RCNP, CISSP, JNCIE, NSE 7 AWS, Google Cloud Experts
Join Partner Network
- Exclusive Discounts/Service
- Credit Terms/Priority Supply In Hongkong
Solutions
Features
Superior Workmanship Guarantees Stable Transmission
Bend insensitive fibre paired with high-performance MPO connectors delivers reliable connectivity for dense data centre and carrier-grade applications.
Overview
The NSComm MPO 16F APC to 8xLC UPC Duplex harness cable is a high-density single mode breakout solution engineered for next-generation 400G/800G data center networks. With one 16-fiber MPO-16 APC (Female) trunk breaking out to eight LC UPC duplex connectors, this harness provides sixteen active fibers for connecting switches, servers, and patch panels that still rely on LC interfaces while supporting OS2 G.657.A1 bend-insensitive performance.
Factory-terminated and fully tested, the MPO–LC harness ensures verified low insertion loss and high return loss to maintain optical integrity in large-scale distributed compute and storage environments. Designed for seamless migration from duplex-based 50/100G Ethernet to parallel 400/800G Ethernet architectures, this harness is ideal for high-density racks, structured cabling systems, equipment rooms, and telecommunication rooms where space optimization and clean cable management are essential.
Need help confirming crossover polarity or mapping to your 400G/800G transceivers? Contact us now, our engineering team can validate compatibility before deployment.
Key Specifications
| Specification | Details |
|---|---|
| Vendor Name | NSComm |
| Product Type | MPO 16F APC to 8xLC UPC Duplex Singlemode Harness Cable |
| Connector A | MPO-16 APC Female (Pinless) with Offset Key, Low Loss |
| Connector B | 8 × LC UPC Duplex connectors |
| Polish Type | APC (MPO) to UPC (LC) |
| Glass Fiber | G.657.A1 bend-insensitive single mode |
| Fiber Mode | OS2 9/125 μm |
| Wavelength | 1310 nm / 1550 nm |
| Fiber Count | 16 Active Fibers (8×LC duplex) |
| Polarity | Crossover |
| Cable Outside Diameter (OD) | 3.0 mm (trunk, typical) |
| Breakout Outside Diameter (OD) | 2.0 mm (LC legs, typical) |
| Breakout Length | 0.5 m (typical) |
| Cable Jacket | Riser-rated, OFNR |
| Minimum Bend Radius | 10 mm |
| MPO Connector Insertion Loss | ≤ 0.35 dB (Typ. 0.15 dB) |
| MPO Connector Return Loss | ≥ 60 dB |
| LC Connector Insertion Loss | ≤ 0.20 dB |
| LC Connector Return Loss | ≥ 50 dB |
| Attenuation @ 1310 nm | ≤ 0.32 dB/km |
| Attenuation @ 1550 nm | ≤ 0.18 dB/km |
| Long-term Tensile Load | 80 N |
| Short-term Tensile Load | 240 N |
| Operating Temperature | -10 to 60 °C (14 to 140 °F) |
| Storage Temperature | -10 to 70 °C (14 to 158 °F) |
| Standards Compliance | MPO interface standards, OS2, RoHS compliant |
| Applications | Duplex-to-parallel migration, 50G/100G to 400G/800G, high-density LC breakout in racks |
Why Choose NSComm MPO 16F to 8xLC UPC Duplex Harness Cables?
-
High-density breakout design – One MPO-16 trunk to eight LC duplex legs enables large port fan-outs while minimizing cable clutter.
-
Ideal for 50/100G → 400/800G migration – Designed for transitions from duplex LC links to parallel optics-based architectures.
-
Low insertion loss performance – Factory-terminated MPO and LC connectors ensure tight optical budgets across all links.
-
Bend-insensitive OS2 G.657.A1 fiber – Maintains signal integrity in tight routing and dense pathways within racks.
-
Crossover polarity for correct channel mapping – Pre-engineered polarity simplifies LC port alignment and reduces errors.
-
Riser-rated OFNR construction – Appropriate for in-cabinet routing and structured cabling in enterprise and cloud data centers.
Length Options
Standard stocked lengths:
Available in optimized lengths for top-of-rack, end-of-row, and structured cabling scenarios with balanced trunk and breakout leg lengths.
Custom lengths:
Custom trunk lengths, breakout leg lengths, LC labeling, and connector configurations are available upon request to match your switching layout and rack-level cable design.
More Details
Quality Certifications










Warranty
100% Low Price Guarantee
Network-switch.com provides high-quality products at low wholesale prices
100% Quality Assurance
All items are ORIGINAL and GENUINE only.
Item conditions are "New Sealed". They are fully tested by Certified CCIE / HCIE / RCNP Engineers.
Free Technical Support
Our FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.
100% Money Back Guarantee
You can contact our customer service team to exchange or return any product that you bought from us.
Standard Warranty Policy
Original New Sealed Enterprise Hardware: 3 Years
Original New Sealed Consumer Devices: 1 Year
The Support Contacts
If your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.
Frequently Questions and Answers
Refund Policy
At Network-switch.com, we aim to provide the best customer experience and ensure that your purchases meet your expectations. If for any reason you are not satisfied with your purchase, please read our return and refund policy below to understand your options.
Returns
You have the right to return products purchased from Network-switch.com under the following conditions:
- Eligibility for Return: Items can be returned within 30 days from the date of delivery, provided that the product is in its original condition, unused, and in the original packaging.
- Non-returnable Items: Certain items such as personalized or custom-made products, and items marked as non-returnable at the time of purchase, cannot be returned.
- Return Process: To initiate a return, please contact our customer support team at help@network-switch.com. You will be provided with instructions on how to return the product and obtain a return authorization number if necessary.
Refunds
- Refund Process: Once we receive your returned item and inspect it, we will process your refund to the original method of payment within 7 business days.
- Refund Conditions: Refunds will be issued for the purchase price of the item, excluding any shipping, handling, or other additional fees. If the product is returned damaged, used, or missing parts, a partial refund may be issued.
Exchanges
If you would prefer to exchange an item for a different size, color, or model, please follow the same return process. Once we receive the returned product, we will send the replacement at no additional charge, based on availability.
Shipping Costs
- Return Shipping Fees: You are responsible for paying the return shipping costs unless the item is defective, damaged, or incorrect.
- Refund for Shipping Costs: Shipping costs are non-refundable, except in the case of defective or incorrect items.
- Restocking Fees: You would be chagred about 30% of the product price when return the item, unless the item is defective, damaged, or incorrect.
Damaged or Incorrect Items
If you receive a damaged or incorrect item, please contact our customer service team within 7 days of receiving the product. We will exchange once the return is received.
Contact Us
If you have any questions or concerns about returns or refunds, please contact us at:
Email: help@network-switch.com
Before returning any products, please contact us to explain the issues you are experiencing. In many cases, we can resolve the problem through technical support, and you won't need to return the product.
If there are irreparable defects in the device, you can return it to us for repair or replacement under our twelve-month warranty. Simply reach out to us, and we will provide you with a return code, our return address, and any additional instructions.
Please do not return any items without first contacting us. We will guide you through the process, including the appropriate shipping methods.