Campus networks are changing fast—dense Wi-Fi, UHD surveillance, and fiber-first buildings are now the norm. The NS-S5750 Switches from Network-Switch are designed for those environments: a same-class, all-optical Campus Switches platform with SFP+ 10G uplinks and integrated Power-over-Fiber (PoF) distribution.
Unlike fixed-brand gear, the NS line ships as your product—front-bezel logo, exterior colorway, labels/packaging, and even pre-loaded software defaults (VLAN plan, QoS, AAA, Syslog/SNMP, uplink LACP templates). In short, you get the performance and resiliency of premium Ethernet switches while delivering a consistent, branded experience in every closet.
The NS-S5750 family mirrors the latest campus PoF switch architecture: 24 × 1G optical downlinks, 4 × 1G/10G SFP+ uplinks, and 24 power output ports over hybrid fiber-power cables. Published specs include up to 100 W per powered port (2,400 W total), 1,500 m PoF reach, 128 Gbps switching capacity, and 96 Mpps forwarding rate; VSU stacking, ERPS rings, L3 routing, and security/QoS are standard.
Product Overview
What makes PoF different. Traditional PoE+ switches push power over copper pairs; PoF centralizes power in one low-voltage, supervised location and carries it to far-edge closets through hybrid cables (fiber for data + copper conductors for DC). That means:
- Longer reach: Up to 1,500 m from the PoF switch to the indoor optical endpoint (SOE) or photoelectric AP—far beyond 100 m copper limits.
- Higher per-port power: Up to 100 W per port with an aggregate 2,400 W budget on the chassis—enough for power-hungry APs, PTZ cameras, or optical endpoints.
- Fewer field electricians: Power originates in equipment rooms; hybrid cable installation simplifies building rollouts and avoids scattered AC in ceiling spaces.
Where NS helps? Because Network-Switch delivers a custom-brand experience, you can ship NS-S5750 with your logo, faceplate color, asset labels, and day-0 software templates (VLANs, LACP on uplinks, ERPS rings, security baselines). That drastically reduces turn-up time—especially across multi-site campus projects.
Models Lineup at a Glance
Model (NS) | Access Ports | Uplink Ports | PoF / Power Outputs | Switching Capacity / Forwarding Rate | Notes |
NS-S5750-24SFP4XS24DP-UP | 24 × 1G SFP downlinks | 4 × SFP+ (1/10G) | 24 × PoF outputs, 100W each, 2400W total | 128 Gbps / 96 Mpps | PoF central power plus optical uplink;1RU;VSU/ERPS. |
NS-S5750-48SFP4XS24DP-UP | 48 × 1G SFP | 4 × SFP+ (1/10G) | 24 × PoF outputs (shared power) | 128 Gbps / 96 Mpps (shared) | Same PoF headroom but drives twice the endpoints. |
NS-S5750-24SFP4XS-UP (Lite PoF) | 24 × 1G SFP | 4 × SFP+ (1/10G) | 12 × reduced PoF outputs (50 W each) | 128 Gbps / 96 Mpps | “Lite” PoF reduces PSU size and cost, still centrally powered. |
NS-S5750-24GT4XS24DP-UP | 24 × 1G RJ45 access | 4 × SFP+ (1/10G) | 24 × PoF outputs | 128 Gbps / 96 Mpps | Full PoF with copper access; good for AP-heavy wings. |
NS-S5750-24SFP4XS-E (No PoF) | 24 × 1G SFP | 4 × SFP+ (1/10G) | None | 128 Gbps / 96 Mpps | Same optics/platform, without power outputs simpler deployment. |
Software & Management Capabilities
The NS-S5750 Switches are managed switches with the control plane you expect in modern Campus Switches:
- Segmentation & resiliency: 802.1Q VLAN (4K), QinQ, private VLAN; STP/RSTP/MSTP; ERPS (G.8032) for sub-50 ms ring recovery; LACP for active-active uplinks.
- Quality & multicast: Eight egress queues; 802.1p/DSCP classification; shaping/policing; IGMP Snooping/querier for IPTV and surveillance hygiene.
- Security: 802.1X (port/MAC), DHCP Snooping, IP Source Guard, DAI, ARP-rate-limit, CPU protection (CPP/NFPP), granular IPv4/IPv6 ACLs, BPDU guard, port security.
- Routing (Layer 3 Switches): IPv4/IPv6 static routes, RIP/RIPng, OSPFv2/v3, IS-IS, and BGP, plus policy routing—fit for routed access or compact distribution roles.
- Operations: Web UI, CLI/SSH, SNMPv1/v2c/v3, RMON, Syslog, sFlow; ZTP/CWMP (TR-069) onboarding; optics telemetry on SFP+ cages; dual-boot flash redundancy.
- Power controls (PoF/PoE management): port priority, scheduled power windows, and warm-start continuity to keep critical endpoints online during maintenance.
Because NS can preload your config (VLAN plan, ERPS ring IDs, LACP groups, AAA order, Syslog/SNMP, port roles), every closet boots with the same posture—no guesswork for contractors.
Deployment Scenarios
All-optical dorms and teaching buildings
Use NS-S5750-24SFP4XS24DP-UP at the building entry to power SOE (indoor optical) switches and APs via hybrid cable. Run 1/10G SFP+ uplinks to your aggregation or collapsed core. With 100 W per hybrid port and 2,400 W total, a single chassis can drive many floors while keeping AC centralized and supervised.
Camera-dense campuses and stadiums
PoF lets you place enclosures exactly where cameras live—on concourses or ceiling trusses—without local AC. Use ERPS rings between building entry closets for fast restoration in case of fiber nicks, and standardize your managed switches templates for IGMP and QoS so multicast storms never reach the core.
Long corridor or parking structures
Copper PoE dies at ~100 m; PoF hybrid cables carry both power and optics up to 1,500 m. Combine LACP on dual fibers for active-active headroom, and rely on dual-boot and PSU redundancy to keep lighting, cameras, and kiosks stable.
Routed access for segmented tenants
Because NS-S5750 Switches are Layer 3 switches, you can terminate VLANs per tenant, run OSPF or BGP northbound, and keep inter-VLAN policy local. This reduces trombone traffic and simplifies change windows—especially when multiple buildings share a collapsed core.
Optics & Cabling Guidance
Uplink Type | Recommended Optics / Cables | Typical Use Case | Notes |
SFP+ (1/10G) on NS-S5750-24SFP4XS24DP-UP | 10G SR/LR SFP+; 1G SFP where needed; DAC/AOC for short links | Building entry to aggregation/core | SR for OM3/OM4 short MMF runs; LR for SMF up to 10 km; hot-plug with optics telemetry supported. |
SFP (1G) downlinks | 1G SX/LX/BiDi SFP to SOE or optical AP endpoints | All-optical floors and wings | BiDi halves fiber strands where plant is tight; follow IEEE/MSA optics guidance. |
Hybrid PoF cabling | Vendor-specified hybrid cable (fiber + copper conductors) | Power + data over long distances | Each hybrid port supports up to 100 W with 2,400 W max per chassis; consult gauge and length tables for loss. |
Redundancy | LACP on SFP+; ERPS rings between buildings | Active-active throughput and fast protection | ERPS provides sub-50 ms recovery; pair with STP edge guards for loop safety. |
NS vs. Fixed-Brand Access Switches
Feature / Aspect | NS-S5750 Switches | Fixed-Brand OEM Campus Switches | Other Third-Party Resellers |
Performance & Specs | Same-class all-optical Fiber Switch with 24 × SFP, 4 × SFP+, PoF up to 100 W/port, 2,400 W total; 128 Gbps / 96 Mpps | OEM-grade specs, often tied to proprietary optics/licensing | Mixed; may be re-badged/refurb gear |
Customization | Full exterior + software defaults (logo, bezel, VLAN/QoS/AAA templates) | Branding/defaults fixed; little personalization | Minimal cosmetics; config done post-purchase |
PoF & Optics Flexibility | Standards-aligned SFP+/SFP; hybrid PoF cabling across 1,500 m; broad optics freedom | Ecosystem locks and certified optics may be required | Varies; optics support often inconsistent |
After-Sales Support | 24/7 helpdesk, fast RMA, ongoing EEPROM/firmware updates | Business-hours support; 5–7-day RMA typical | Limited support; 7–14-day RMA common |
Pricing & TCO | Typically ~30% below OEM; no hidden licenses; faster turn-ups | Premium list price; feature licenses possible | Slightly under OEM with fewer guarantees |
Inventory & Lead Time | Custom SKUs; pre-configured ready-to-deploy | Standard SKUs only | Inconsistent stock; long-tail lead times |
Hardware Highlights & Reliability
- Triple hot-swap PSU slots (1+N) for power redundancy and simplified field replacement; dual-boot flash to protect against corrupted images.
- Fan telemetry and temperature alarms for proactive maintenance; 0–45 °C operating range with altitude de-rating; compact 1RU depth for crowded racks.
- VSU virtualization lets you manage multiple building entry switches as one node; link bundling across chassis keeps traffic flowing during maintenance.
Operations, Visibility & Security
- Zero-touch day-0: We ship your standard image/config—VLAN plan (e.g., 10-User / 20-Voice / 30-Video), ERPS ring IDs, LACP on uplinks, AAA order, SNMP/Syslog endpoints, and port roles—so installers just land fiber and power.
- Troubleshooting speed: With Web/CLI/SSH, SNMP, Syslog/RMON, and sFlow, plus optics power readouts on SFP+ cages and temperature/fan alarms, you can diagnose remotely—no late-night truck rolls.
- Edge hygiene: Enable DHCP Snooping + IP Source Guard + DAI on day-0; add storm controls and ACLs at ingress; use CPP/NFPP to shield the control plane from floods.
FAQs
Q1: How far can a PoF link run?
A: Up to 1,500 m from the PoF switch to the indoor optical endpoint in the published solution design.
Q2: How much power can each hybrid port deliver?
A: Up to 100 W per port, with an aggregate 2,400 W chassis budget (24 × 100 W).
Q3: Are the uplink cages true 10G?
A: Yes, 4 × SFP+ uplinks negotiate 1G/10G; use SR/LR optics (or DAC/AOC short runs) to match your fiber plant.
Q4: Is this a “PoE switch”?
A: Functionally yes at the edge, NS-S5750 Switches supply DC over hybrid cable (PoF) to far-edge optical endpoints and APs, with scheduled power, priorities, and warm-start continuity similar to PoE+ switches management.
Q5: Can multiple chassis act as one?
A: Yes. VSU stacking/virtualization provides single-pane management and fast failover; combine with ERPS for ring protection.
Conclusion
If you’re building Fiber Switch-first campuses, upgrading dorms, or consolidating edge power, the NS-S5750 Switches give you all-optical access with integrated PoF, plus the customization that makes large rollouts sane.
With 24 × SFP downlinks, 4 × SFP+ uplinks, 24 hybrid power outputs up to 100 W/port, and Layer 3 switches features (OSPF/IS-IS/BGP, VSU, ERPS), Network-Switch lets you scale without lock-in—and deliver a branded, predictable experience on day one.
Did this article help you or not? Tell us on Facebook and LinkedIn . We’d love to hear from you!