NSComm LC UPC to LC UPC Duplex Standard Clip Uniboot Multimode(OM4) Fiber Patch Cable, 2.0mm OFNR

Proven Expertise, Trusted Solutions
- 8 Years, 100+ Countries
- 10000+ Customers/Projects
- CCIE, HCIE, H3CIE, RCNP, CISSP, JNCIE, NSE 7 AWS, Google Cloud Experts
Join Partner Network
- Exclusive Discounts/Service
- Credit Terms/Priority Supply In Hongkong
Solutions
Features
Build a Stable and Robust Fiber Optic Network
High-quality tight-buffered cable protects the fibre optic core, and increases the strength and durability of the fibre.
Carrier-grade Cable Ensures Transmission Quality
Superior cable assemblies reduce light loss and easily meet your diverse cabling requirements.
Color-Coded Cable Jacket
A fibre cable's jacket colour is typically defined by the fibre type, and can differ based on mode and performance level.
A-to-B Fiber Polarity in Fiber Applications
To help the industry select and install the right components to maintain proper polarity, TIA-568-C standards recommend the A-B polarity scenario for duplex patch cords.
Meet the Various Indoor Installation Needs
Ceiling Application
Floor Application
In-Cabinet Application
Overview
The NSComm LC UPC to LC UPC Duplex Standard Clip Uniboot Multimode (OM4) Fiber Patch Cable is a space-saving, high-density cabling solution designed for modern data centers and enterprise networks. Its uniboot structure routes both fibers within a single 2.0mm jacket, significantly reducing cable congestion on front panels, improving airflow, and simplifying cable management in high-port-count environments.
Built with bend-insensitive OM4 50/125 μm multimode fiber and LC UPC connectors at both ends, this patch cable delivers low insertion loss and stable return loss, making it ideal for 10/40/100G short-reach Ethernet applications using SR/SR4 optics, QSFP+/SFP+ transceivers, and high-density LC patching.
The riser-rated (OFNR) jacket and tight-buffered construction ensure mechanical robustness while maintaining the flexibility needed for routing through dense cable managers and narrow pathways.
If you are planning high-density LC uniboot deployments or OM4 upgrades, our team can help validate compatibility, layout, and cable selection before rollout.
Key Specifications
| Specification | Details |
|---|---|
| Vendor Name | NSComm |
| Product Type | LC UPC to LC UPC Duplex Standard Clip Uniboot Multimode (OM4) Fiber Patch Cable |
| Connector Type | LC UPC to LC UPC |
| Fiber Count | Duplex |
| Fiber Grade | Bend-insensitive multimode fiber |
| Fiber Mode | OM4 50/125 μm Multimode |
| Durability | 1000 cycles |
| Insertion Loss | < 0.20 dB |
| Return Loss | ≥ 30 dB |
| Attenuation @ 850 nm | 3.0 dB/km |
| Attenuation @ 1300 nm | 1.5 dB/km |
| Cable Outside Diameter (OD) | 2.0 mm |
| Min. Bend Radius (Fiber Core) | 7.5 mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Tensile Strength (Long/Short Term) | 60/100 N |
| Cable Jacket | Riser (OFNR) |
| Operating Temperature | -10 to 70 °C |
| Storage Temperature | -20 to 70 °C |
| Applications | High-density OM4 LC patching, 10/40/100G SR links, QSFP+/SFP+ MM connections |
Why Choose NSComm LC UPC to LC UPC Duplex Uniboot OM4 Patch Cables?
-
Space-saving uniboot construction – Both fibers share a single 2.0mm jacket, reducing cable bulk and improving rack airflow.
-
Optimized for 40/100G OM4 deployments – OM4 multimode fiber provides higher bandwidth and longer reach than OM3 for SR links.
-
Bend-insensitive multimode fiber – Maintains low attenuation in tight routing paths common in high-density data centers.
-
Low-loss LC UPC terminations – <0.2 dB insertion loss and solid return loss support clean, stable multimode signal delivery.
-
Riser-rated OFNR jacket – Suitable for vertical risers and structured cabling in enterprise and cloud data center environments.
Length Options
Standard stocked lengths:
Available in commonly used uniboot lengths suited for switch-to-switch, switch-to-panel, and panel-to-panel connections in dense LC environments.
Custom lengths:
Custom lengths, jacket colors, labeling, and polarity options are available on request to align with your specific rack layout, cabling standards, and high-density design.
More Details
Quality Certifications










Warranty
100% Low Price Guarantee
Network-switch.com provides high-quality products at low wholesale prices
100% Quality Assurance
All items are ORIGINAL and GENUINE only.
Item conditions are "New Sealed". They are fully tested by Certified CCIE / HCIE / RCNP Engineers.
Free Technical Support
Our FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.
100% Money Back Guarantee
You can contact our customer service team to exchange or return any product that you bought from us.
Standard Warranty Policy
Original New Sealed Enterprise Hardware: 3 Years
Original New Sealed Consumer Devices: 1 Year
The Support Contacts
If your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.
Frequently Questions and Answers
Refund Policy
At Network-switch.com, we aim to provide the best customer experience and ensure that your purchases meet your expectations. If for any reason you are not satisfied with your purchase, please read our return and refund policy below to understand your options.
Returns
You have the right to return products purchased from Network-switch.com under the following conditions:
- Eligibility for Return: Items can be returned within 30 days from the date of delivery, provided that the product is in its original condition, unused, and in the original packaging.
- Non-returnable Items: Certain items such as personalized or custom-made products, and items marked as non-returnable at the time of purchase, cannot be returned.
- Return Process: To initiate a return, please contact our customer support team at help@network-switch.com. You will be provided with instructions on how to return the product and obtain a return authorization number if necessary.
Refunds
- Refund Process: Once we receive your returned item and inspect it, we will process your refund to the original method of payment within 7 business days.
- Refund Conditions: Refunds will be issued for the purchase price of the item, excluding any shipping, handling, or other additional fees. If the product is returned damaged, used, or missing parts, a partial refund may be issued.
Exchanges
If you would prefer to exchange an item for a different size, color, or model, please follow the same return process. Once we receive the returned product, we will send the replacement at no additional charge, based on availability.
Shipping Costs
- Return Shipping Fees: You are responsible for paying the return shipping costs unless the item is defective, damaged, or incorrect.
- Refund for Shipping Costs: Shipping costs are non-refundable, except in the case of defective or incorrect items.
- Restocking Fees: You would be chagred about 30% of the product price when return the item, unless the item is defective, damaged, or incorrect.
Damaged or Incorrect Items
If you receive a damaged or incorrect item, please contact our customer service team within 7 days of receiving the product. We will exchange once the return is received.
Contact Us
If you have any questions or concerns about returns or refunds, please contact us at:
Email: help@network-switch.com
Before returning any products, please contact us to explain the issues you are experiencing. In many cases, we can resolve the problem through technical support, and you won't need to return the product.
If there are irreparable defects in the device, you can return it to us for repair or replacement under our twelve-month warranty. Simply reach out to us, and we will provide you with a return code, our return address, and any additional instructions.
Please do not return any items without first contacting us. We will guide you through the process, including the appropriate shipping methods.